Name File Type Size Last Modified
Fig1SIa.JPG image/jpeg 6.5 MB 04/15/2020 09:23:PM
Fig1SIb.JPG image/jpeg 4.2 MB 04/16/2020 07:45:PM
Fig1SIc.JPG image/jpeg 4.3 MB 04/16/2020 07:45:PM
Fig1d.tif image/tiff 865.3 KB 07/16/2020 11:36:PM
Fig1d_inset.tif image/tiff 675.5 KB 04/06/2020 01:07:PM
Fig1e.jpg image/jpeg 95.1 KB 04/15/2020 08:58:PM
Fig1e_inset.tif image/tiff 817.2 KB 04/06/2020 12:51:PM
Fig2SIa.JPG image/jpeg 4.4 MB 04/04/2020 01:46:PM
Fig2SIb.JPG image/jpeg 4.6 MB 04/16/2020 07:46:PM
Fig2b.PNG image/png 1.6 MB 04/16/2020 07:48:PM

Project Citation: 

Chacón-Torres, Julio C., Reinoso, C., Navas-Leon, Daniela G., Briceño, Sarah, and González, Gema. Optimized and scalable synthesis of magnetic nanoparticles for RNA extraction in response to developing countries’ needs for the detection and control of SARS-CoV-2. Ann Arbor, MI: Inter-university Consortium for Political and Social Research [distributor], 2020-07-17. https://doi.org/10.3886/E120310V1

Project Description

Summary:  View help for Summary Database of experimental results along the synthesis of functionalized magnetic nanoparticles for the RNA magnetic extraction methodology in real time RT-PCR for the clinical diagnosis of COVID-19 including:
  • Scanning electron micrographs.
  • Raman spectra taken at 532nm excitation waveleght.
  • Optical micrographs.
  • Infrared spectra.
  • X-ray photoelectron spectra.
  • Real time RT-PCR amplification fluorescence spectra.
  • Laboratory pictures.

Scope of Project

Subject Terms:  View help for Subject Terms Nanoparticles; Physics; Materials Science; Health; COVID-19
Geographic Coverage:  View help for Geographic Coverage Ecuador, Developing countries, Latin America, Worldwide
Time Period(s):  View help for Time Period(s) 4/3/2020 – 6/26/2020
Collection Date(s):  View help for Collection Date(s) 4/3/2020 – 6/26/2020
Universe:  View help for Universe Synthesis and characterization of nanoparticles applied research.
Data Type(s):  View help for Data Type(s) images: photographs, drawings, graphical representations; observational data; other
Collection Notes:  View help for Collection Notes ONELABT provided some chemicals for these experiments
Claudio Maldonado 
conducted the RT-PCR tests.
InnovativeHealth LATAM supported the RT-PCR collection tests.

Methodology

Sampling:  View help for Sampling Infrared spectroscopy. The infrared analysis of the samples was done using an Agilent Technologies spectrometer Cary 360 with a diamond attenuated total reflectance (ATR) accessory and resolution of 4 cm-1. For each spectrum 32 scans  acquisitions were compiled in a range between 400 and 4000 cm-1.
Raman spectroscopy. The spectroscopic Raman detection was carried out under ambient conditions using a HORIBA LabRam spectrometer with a 514 nm and 633 nm excitation wavelengths at ~0.65 mW and 1.5 mW between -50 and 4,000 cm-1. To avoid laser-induced damage on the samples the laser power was kept below 1 mW. Raman measurements were carried out using a micro-Raman setup with a 100X short distance objective in backscattering geometry. A charge-coupled device is used to detect the signal after analyzing the signal via a monochromator similar to previous Raman spectroscopy studies we have conducted [13]. The spectrometer was calibrated in frequency with the Rayleigh peak to be set at 0 cm-1.
X-ray photoelectron spectroscopy. The surface chemistry characterization was recorded by using X-Ray Photoelectron Spectroscopy (XPS) PHI VersaProbe III (Physical-Electronics) equipped with a 180 hemispherical electron energy analyzer and excited by a monochromatized Al-K𝛼 source with an energy 1486.6 eV. Its energy analyzer operates in the pass energy mode at 280 eV for Survey and 55 eV for high resolution. The analysis spot had a diameter of 50 μm and 45° detection angle relative to the substrate surface. Atomic concentration for each element was calculated using Mutipak Version 9.8.0.19 (Ulvac-phi, Inc.) this software uses the peak intensity (peak area) in units of counts per second taking into account the specific relativity sensitivity factor for each element.25,26  Background subtraction was not necessary due the high intensity peaks and non important energy losses prior to emission from the sample.
RNA extraction and Real Time RT-PCR. To evaluate the effectiveness of the Poly-NH2-MNP, a commercial IVD kit was used with already standardized reagents and whose only differential variables were the Poly-NH2-MNP in different concentrations and in different extraction procedures.The steps of the kit extraction protocol were followed and 15, 20 and 25 µL (microliters) of Poly-NH2-MNP were added to our nasopharyngeal swab samples along with a positive control of a known sample with the presence of the SARS-CoV-2 virus.After obtaining the genetic material, 8 µL of extracted RNA (stored between 2-8 °C) was used to start the PCR with a final volume of 20 µL.The PCR was given under the following thermocycling from a commercial kit.

Related Publications

Published Versions

Export Metadata

Report a Problem

Found a serious problem with the data, such as disclosure risk or copyrighted content? Let us know.

This material is distributed exactly as it arrived from the data depositor. ICPSR has not checked or processed this material. Users should consult the investigator(s) if further information is desired.